PAP Temperature Control Type - Air Cooled

Air Cooled

Specification table

Model PAP05A1 PAP05A1-F
Performance
Specifications
Settable temperature range (1)

°C

18 - 30
Temperature control accuracy (2) °C ± 0.1
Cooling + heating capacity (50/60 Hz) kW 2.3 / 2.6
(Maximum cooling capacity) (kW) (1.6) / (1.8)
Rated treatment volume m3/min 3 to 5
Maximum external static pressure (3) Pa 110 620
Environmental
Conditions
Ambient temperature and
humidity range (suction air) (1)
°C,% 15 to 35, 30 to 70
Suction temperature change gradient °C/h Within ± 1
Suction humidity change gradient %/H Within ± 5
External dimensions (height x depth x width) (4) mm 1140 × 700 × 600 1423 × 700 × 600
Product weight kg (130) (155)
Control air outlet mm φ 100 Built-in φ100 HEPA filter
Power
Specifications
Power supply (6) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (7) kW 1.4
Current (7) A 6.2
Power supply capacity (8) kVA 2.2
Noise value (50/60 Hz) (9) dB 66/66 71/71
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 0.7
Model PAP10A1 PAP10A1-F
Performance
Specifications
Settable temperature range (1) °C 18 - 30
Temperature control accuracy (2) °C ± 0.1
Cooling + heating capacity (50/60 Hz) kW 4.7 / 5.3
(Maximum cooling capacity) (kW) (3.2) / (3.6)
Rated treatment volume m3/min 7 to 10
Maximum external static pressure (3) Pa 250 560
Environmental
Conditions
Ambient temperature and
humidity range (suction air) (1)
°C,% 15 to 35, 30 to 70
Suction temperature change gradient °C/h Within ± 1
Suction humidity change gradient %/H Within ± 5
External dimensions (height x depth x width) (4) mm 1305 × 822 × 661 1565 × 822 × 661
Product weight kg (185) (210)
Control air outlet mm φ 150 Built-in φ 150 HEPA filter
Power
Specifications
Power supply (6) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (7) kW 1.8
Current (7) A 7.5
Power supply capacity (8) kVA 2.6
Noise value (50/60 Hz) (9) dB 68/68 73/73
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 1.7
Model PAP20A PAP20A-F
Performance
Specifications
Settable temperature range(1) °C 18 - 30
Temperature control accuracy (2) °C ± 0.1
Cooling + heating capacity (50/60 Hz) kW 9.4 / 10.5
(Maximum cooling capacity) (kW) (6.5) / (7.2)
Rated treatment volume m3/min 13 - 20
Maximum external static pressure (3) Pa 250 690
Environmental
Conditions
Ambient temperature and
humidity range (suction air) (1)
°C,% 15 to 35, 30 to 70
Suction temperature change gradient °C/h Within ± 1
Suction humidity change gradient % / H Within ± 5
External dimensions (height x depth x width) (4) mm 1610 × 1150 × 770 2010 × 1150 × 770
Product weight kg (290) (365)
Control air outlet mm φ 200 φ200 with HEPA filter box (5)
Power
Specifications
Power supply (6) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (7) kW 3.9
Current (7) A 14.9
Power supply capacity (8) kVA 5.2
Noise value (50/60 Hz) (9) dB 69/69 76/76
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 3.0
1 It does not represent a controllable temperature range. The controllable temperature range varies depending on the suction air temperature and humidity.
2 When suction air temperature and humidity are stable. Ejection port 1 point, accuracy of controller display value.
3 External static pressure when operated at the rated rated air volume by throttling on the control air discharge side.
4 The height includes the discharge port.
5 The HEPA filter box is shipped separately from the main body, so installation on site is necessary.
6 The phase unbalance of power supply voltage should be within ± 3%.
7 Maximum value within specification range.
8 Maximum operation current within specified range.
9 By installing a muffling suction duct it is possible to lower the noise value.

External Dimensions