PAP Temperature And Humidity Control Type - Water Cooled

Water Cooled

Specification table

Model PAP05A1-KW PAP05A1-FKW
Performance
Specifications
Setting temperature / humidity range (1) ° C,% 18 to 30, 40 to 65 (75)
Temperature / humidity control accuracy (2) ° C,% ± 0.1, ± 1.0
Cooling + heating capacity (50/60 Hz) kW 3.2 / 3.2
(Maximum cooling capacity) (kW) (2.0)
Rated treatment volume m 3 / min 3 to 5
Maximum external static pressure (3) Pa 110 620
Environmental
Conditions
Ambient temperature and humidity range (suction air) (1) ° C,% 15 to 35, 30 to 70
Suction temperature change gradient ° C / h Within ± 1
Suction humidity change gradient % / H Within ± 5
Coolant water temperature change gradient ° C / h Within ± 3
External dimensions (height x depth x width) (4) mm 1610 × 750 × 610 1830 × 750 × 610
Product weight kg 180 205
Control air outlet mm φ 100
Built-in φ 100 HEPA filter
Cooling
Water
Supply amount (6) m 3 / h 1.0
Supply temperature range 15 to 32
Supply pressure MPa 0.69 or less
Inlet / outlet pressure difference MPa 0.2 or more
Connection port diameter Rc 1/2
Humidification
water
Water quality Pure water (electric conductivity 1 to 10 S / cm)
Maximum humidification capacity (7) kg / h 2.5
Supply temperature range 10 to 40
Supply pressure range MPa 0.1 to 0.5
Connection port diameter Rc 1/4
Humidification
air
Maximum consumption (8) NL / min 23
Supply temperature range 20 to 40
Supply pressure range MPa 0.40 to 0.93
Connection port diameter Rc 1/4
Power
specifications
Power supply (9) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (1)0 kW 1.5
Current (1)0 A 6.3
Power supply capacity (1)1 kVA 2.2
Noise value (50/60 Hz) (1)2 dB 68/68 73/73
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 0.7
Model PAP10A1-KW PAP10A1-FKW
Performance
Specifications
Setting temperature / humidity range (1) ° C,% 18 to 30, 40 to 65 (75)
Temperature / humidity control accuracy (2) ° C,% ± 0.1, ± 1.0
Cooling + heating capacity (50/60 Hz) kW 6.5 / 6.5
(Maximum cooling capacity) (kW) (4.0)
Rated treatment volume m 3 / min 7 to 10
Maximum external static pressure (3) Pa 200 560
Environmental
Conditions
Ambient temperature and humidity range (suction air) (1) ° C,% 15 to 35, 30 to 70
Suction temperature change gradient ° C / h Within ± 1
Suction humidity change gradient % / H Within ± 5
Coolant water temperature change gradient ° C / h Within ± 3
External dimensions (height x depth x width) (4) mm 1670 × 940 × 664 2076 × 940 × 664
Product weight kg 235 280
Control air outlet mm 150 150 with
HEPA filter box (5)
Cooling
Water
Supply amount (6) m 3 / h 1.5
Supply temperature range 15 to 32
Supply pressure MPa 0.69 or less
Inlet / outlet pressure difference MPa 0.2 or more
Connection port diameter Rc 3/4
Humidification
water
Water quality Pure water (electric conductivity 1 to 10 S / cm)
Maximum humidification capacity (7) kg / h 5.0
Supply temperature range 10 to 40
Supply pressure range MPa 0.1 to 0.5
Connection port diameter Rc 1/4
Humidification
air
Maximum consumption (8) NL / min 38
Supply temperature range 20 to 40
Supply pressure range MPa 0.40 to 0.93
Connection port diameter Rc 1/4
Power
specifications
Power supply (9) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (1)0 kW 2.2
Current (1)0 A 7.8
Power supply capacity (1)1 kVA 2.8
Noise value (50/60 Hz) (1)2 dB 70/70 75/75
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 1.7
Model PAP20A1-KW PAP20A1-FKW
Performance
Specifications
Setting temperature / humidity range (1) ° C,% 18 to 30, 40 to 65 (75)
Temperature / humidity control accuracy (2) ° C,% ± 0.1, ± 1.0
Cooling + heating capacity (50/60 Hz) kW 13.0 / 13.0
(Maximum cooling capacity) (kW) (8.0)
Rated treatment volume m 3 / min 13 - 20
Maximum external static pressure (3) Pa 250 690
Environmental
Conditions
Ambient temperature and humidity range (suction air) (1) ° C,% 15 to 35, 30 to 70
Suction temperature change gradient ° C / h Within ± 1
Suction humidity change gradient % / H Within ± 5
Coolant water temperature change gradient ° C / h Within ± 3
External dimensions (height x depth x width) (4) mm 1809 × 973 × 773 2209 × 973 × 773
Product weight kg 300 370
Control air outlet mm 200 200 with
HEPA filter box (5)
Cooling
Water
Supply amount (6) m 3 / h 2.2
Supply temperature range 15 to 32
Supply pressure MPa 0.69 or less
Inlet / outlet pressure difference MPa 0.2 or more
Connection port diameter Rc 3/4
Humidification
water
Water quality Pure water (electric conductivity 1 to 10 S / cm)
Maximum humidification capacity (7) kg / h 10.0
Supply temperature range 10 to 40
Supply pressure range MPa 0.1 to 0.5
Connection port diameter Rc 1/4
Humidification
air
Maximum consumption (8) NL / min 80
Supply temperature range 20 to 40
Supply pressure range MPa 0.40 to 0.93
Connection port diameter Rc 1/4
Power
specifications
Power supply (9) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (1)0 kW 3.8
Current (1)0 A 13.5
Power supply capacity (1)1 kVA 4.7
Noise value (50/60 Hz) (1)2 dB 72/72 78/78
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 1.7
Model PAP40A-KW PAP40A-FKW
Performance
Specifications
Setting temperature / humidity range (1) ° C,% 18 to 30, 40 to 65 (75)
Temperature / humidity control accuracy (2) ° C,% ± 0.1, ± 1.0
Cooling + heating capacity (50/60 Hz) kW 22.0 / 22.0
(Maximum cooling capacity) (kW) (16.0)
Rated treatment volume m 3 / min 25 to 40
Maximum external static pressure (3) Pa 300 1000
Environmental
Conditions
Ambient temperature and humidity range (suction air) (1) ° C,% 15 to 35, 30 to 70
Suction temperature change gradient ° C / h Within ± 1
Suction humidity change gradient % / H Within ± 5
Coolant water temperature change gradient ° C / h Within ± 3
External dimensions (height x depth x width) (4) mm 1800 × 1300 × 1084 2323 × 1300 × 1084
Product weight kg 540 640
Control air outlet mm 350 350
HEPA with filter box (5)
Cooling
Water
Supply amount (6) m 3 / h 3.0
Supply temperature range 15 to 32
Supply pressure MPa 0.69 or less
Inlet / outlet pressure difference MPa 0.2 or more
Connection port diameter Rc 1
Humidification
water
Water quality Pure water (electric conductivity 1 to 10 S / cm)
Maximum humidification capacity (7) kg / h 20.0
Supply temperature range 10 to 40
Supply pressure range MPa 0.1 to 0.5
Connection port diameter Rc 1/4
Humidification
air
Maximum consumption (8) NL / min 200
Supply temperature range 20 to 40
Supply pressure range MPa 0.45 to 0.93
Connection port diameter Rc 1/4
Power
specifications
Power supply (9) V (Hz) Three phases 200 ± 10% (50/60)
Power consumption (1)0 kW 6.6
Current (1)0 A 26.0
Power supply capacity (1)1 kVA 9.0
Noise value (50/60 Hz) (1)2 dB 75/75 83/83
Operation control system Heat pump balance control
Refrigerant R410A
Refrigerating compressor output kW 3.0
1 It does not represent controllable temperature and humidity range. The controllable temperature and humidity range varies depending on the suction air temperature and humidity. (When humidity setting range is 65 ~ 75%, it becomes steam humidification system.)
2 When suction air temperature humidity, cooling water temperature and cooling water supply quantity are stable. Ejection port 1 point, accuracy of controller display value.
3 External static pressure when operated at the rated rated air volume by throttling on the control air discharge side.
4 The height includes the discharge port.
5 The HEPA filter box is shipped separately from the main body, so installation on site is necessary.
6 Maximum rated processing volume at maximum cooling, cooling water inlet / outlet temperature difference 6.5 ° C.
7 Maximum humidification operation within specification range.
8 Please supply clean compressed air processed with filter etc. The degree of cleanliness of compressed air should be based on the degree of cleanliness required in the blowing area.
9 The phase unbalance of power supply voltage should be within ± 3%.
10 Maximum value within specification range.
11 Maximum operation current within specified range.
12 By attaching the muffler duct, it is possible to lower the noise value

External Dimensions