ORION® DUAL CHANNEL CHILLERS

ORION® DUAL CHANNEL CHILLERS

DUAL CHANNEL CHILLERS

Air Cooled

  • 1 : RKS1500G-MV-2CH
  • 2 : RKE2200B1-V-2CH
  • 3 : RKE3750B-V-2CH
  • 4 ~ 6 : 6RKE5500B-V-2CH
  • 7 ~ 10 : RKE11000A-V-ISP

Water Cooled

  • 1 ~ 2 : RKE2200B1-VW-ISP
  • 3 : RKE3750A-VW-ISP
  • 4 ~ 6 : RKE5500A-VW-ISP
  • 7 ~ 8 : RKE7500A-VW-ISP
  • 10 ~ 12 : RKE11000A-VW-ISP
DOWNLOAD BROCHURE

Space Saving

Avoids the Trouble of Setting Up 2 Chillers

Oscillator AND Optical System Cooling in One Package! (Individual control from dual tanks and dual pumps.)

Only Requires the Maintenance Space of a Single Unit.

Footprint Reduced as much as 30 % Over Previous Models!

Convenient

Easy and Reliable Water Management

Copperless Optical System Circuit (Deionized Water Spec.) Standard

(SUS Circuit, Ion Exchange Resin, Electrical Conductivity Meter)

Meets the Demands of Your Oscillator

Standard-Equipped with Startup Heater and Relief Valve

*Only for the optical system. Available as an option for the oscillator.

Many Options Available!

Water Filter, Flow Rate Alarm, etc. Customize to meet the demands of your oscillator and processing equipment.

Top Class Energy SavingsBuilt-In TESC (Three Eco Speed Control) For Industry

The inverter controlled compressor and fan are automatically controlled to run at the minimum operating speed for optimized refrigeration cycle operation. And we've made it easy to set the minimum pump speed. Eco operation achieved with three power sources.

Air Cooled Models

Laser Oscillator Output kW 1 2 3 4~6 7~10
Chiller Model RKE
1500G-MV-2CH
RKE
2200B1-V-2CH
RKE
3750B-V-2CH
RKE
5500B-V-2CH
RKE
11000B-V-2CH
Performance Specifications
Cooling Capacity kW 3.9/4.3 7.7 11.2 19.3 36.2
Oscillator (4) Circulating Water kW Clean Water
Temp. Setting Range °C 5 - 35 3 - 35
Temp. Precision °C ± 0.1 (When load is stable)
Operating Pressure MPa 0.5 or lower
Operating Flow
Rate (0.5MPa) *2
L/min 12 / 21 28 / 43 15 - 50 60 - 95 100 - 200
Optical System (5) Cooling Capacity kW 1 2
Circulating Water Deionized Water
(Control range when shipped from the factory: 30 - 50 µS/cm)
Operating Temp.
Setting Range
°C 25 - 40
(Oscillator Water Temp. Setting °C or higher)
Temp. Precision °C ± 1°C (When load is stable)
Operating Pressure MPa 0.5 or lower
Operating Flow Rate (0.5MPa) *3 L/min 24/52
Power Specifications
Power
Source (2)
V (Hz) Three-phase 200 (50/60)
Power consumption (1) kW 2.6 / 3.2 5.5 / 6.0 6.3 / 6.7 10.7 / 11.1 15.3 / 15.7
Current (1) A 12.6 / 13.2 22 / 23 22.5 / 22.5 36.1 / 36.1 53 / 53
Power Supply
Capacity
kVA 6 8.7 9.2 13.2 21.7
Environmental Conditions
Refrigeration
Compressor
kW 1.8 1.7 3.0 7.46
Condenser Fin and Tube Forced Air Cooling
Oscillator (4) Evaporator Construction Plate Type
Materials SUS316 (Brazing Cu)
Optical System (5) Evaporator Construction Shell and coil Plate Type
Materials SUS304, Resin SUS316 (Brazing SUS)
Oscillator (4) Discharge Pump Construction Cascade Multistage Centrifugal Immersion Type
Output kW 0.4 0.75 1.1 (Inverter) 2.0 (Inverter) 2.5 (Inverter)
Optical System (5) Discharge Pump Construction Multistage Centrifugal Immersion Type (SUS)
Output kW 0.65/1.05
Oscillator (4) Heater kW 2.0 3.0 5.0
Optical System (5) Heater kW 1.0
Fan Output kW 0.025 × 2 0.11/0.14 0.4 (Inverter) 0.75 (Inverter) 0.4 × 2 (Inverter)
Oscillator (4) Water Tank Capacity L Approx. 20 Approx. 20 Approx. 60 Approx. 90 Approx. 100
Optical System (5) Water Tank Capacity L Approx. 10
Refrigerant R410A
External dimensions
(H × L × W)
mm 1140×
700×627
1080×
1200×660
1410×
752×950
1700×
854×1100
1700×
854×1610
  • 1 When operating under the following conditions: ambient temperature: 32 °C (1500 model: 25 °C); water temperature: 20 °C. The cooling capacity is the combined power of the oscillator and optical circuit, and is at least 95% of the noted power.
  • 2 The optical system cooling water flow rate will be 0 - 10 L/min, and therefore the actual flow rate for the oscillator system outside the product will be reduced by 0 - 10 L/min.
  • 3 The ion exchange resin flow rate will be 0 - 2 L/min, and therefore the flow rate for the optical system outside the product will be reduced by 0 - 2 L/min.
  • 4 Circuit 1.
  • 5 Circuit 2.
  • *Specifications may be improved without notice.
  • *External dimensions are for reference only.

Equipment Table

Water Cooled Models

Laser Oscillator Output kW 1 2 3 4~6 7~10
Chiller Model RKE2200B1-VW-2CH RKE3750B-VW-2CH RKE5500B-VW-2CH RKE7500B-VW-2CH RKE11000B-VW-2CH
Performance Specifications
Cooling Capacity kW 9.4 13.1 22.4 26.3 42.0
Oscillator (4) Circulating Water kW Clean Water
Temp. Setting Range °C 5 - 35 3 - 35
Temp. Precision °C ± 0.1 (When load is stable)
Operating Pressure MPa 0.5 or lower
Operating Flow
Rate (0.5MPa) *2
L/min 28 / 43 15 - 50 60 - 95 100 - 200
Optical System (5) Cooling Capacity kW 1 2
Circulating Water Deionized Water
(Control range when shipped from the factory: 30 - 50 µS/cm)
Operating Temp.
Setting Range
°C 25 - 40
(Oscillator Water Temp. Setting +5 °C or higher)
Temp. Precision °C ± 1°C (When load is stable)
Operating Pressure MPa 0.5 or lower
Operating Flow Rate (0.5MPa) *3 L/min 24/52
Power Specifications
Power
Source (2)
V (Hz) Three-phase 200 (50/60)
Power
consumption (1)
kW 4.5 / 5.0 6.0 / 6.4 9.7 / 10.1 11.0 / 11.4 13.6 / 14.0
Current (1) A 20.0 / 20.0 25.2 / 25.2 37.8 / 37.8 39.2/ 39.0 47.0 / 47.0
Power Supply
Capacity
kVA 7.7 10.2 14.4 14.8 19.7
Environmental Conditions
Refrigeration
Compressor
kW 1.7 3.0 4.6 7.46
Condenser Double Pipe Water Cooling
Oscillator (4) Evaporator Construction Plate Type
Materials SUS316 (Brazing Cu)
Optical System (5) Evaporator Construction Shell and coil Plate Type
Materials SUS316, Resin SUS316 (Brazing SUS)
Oscillator (4) Discharge Pump Construction Cascade Multistage Centrifugal Immersion Type
Output kW 0.75 1.1 (Inverter) 2.0 (Inverter) 2.5 (Inverter)
Optical System (5) Discharge Pump Construction Multistage Centrifugal Immersion Type (SUS)
Output kW 0.65/1.05
Oscillator (4) Heater kW 2.0 3.0 5.0
Optical System (5) Heater kW 1.0
Cooling water flow °C/h 1.8 2.4 3.4 3.5 4.2
Oscillator Water Tank Capacity L Approx. 20 Approx. 60 Approx. 90 Approx. 90 Approx. 100
Optical System Water Tank Capacity L Approx. 10
Refrigerant R410A
External dimensions (H × L × W) mm 1080×
1200×660
1410×
752×950
1700×
854×1100
1700×
854×1100
1410×
854×1610
  • 1 When operating under the following conditions: cooling water temperature: 20 °C. Cooling capacity is the combined power of the oscillator and optical circuit, and is at least 95% of the noted power. 32 °C, Water temperature: 20 °C
  • 2 The optical system cooling water flow rate will be 0 - 10 L/min, and therefore the actual flow rate for the oscillator system outside the product will be reduced by 0 - 10 L/min.
  • 3 The ion exchange resin flow rate will be 0 - 2 L/min, and therefore the flow rate for the optical system outside the product will be reduced by 0 - 2 L/min.
  • 4 Circuit 1.
  • 5 Circuit 2.
  • *Specifications may be improved without notice.
  • *External dimensions are for reference only.

Air Cooled Models

Water Cooled Models