ORION® Heavy Duty Water Cooled Chillers

Heavy Duty DC Inverter Chiller - Water Cooled Series

Bulit In Tank

Refrigeration Equipment

Cooling capacity:14.1 KW - 48.0KW

Models Air cooled
  • RKE3750B-VW-G1 / G2 (with casters)
  • RKE5500B-VW
  • RKE7500B-VW
  • RKE11000B-VW
  • RKE15000B-VW

Specification Chart

Model Water-cooled type
RKE3750B-VW
G 1 · G 2
(with casters)
RKE5500B-VW RKE7500B-VW RKE11000B-VW RKE15000B-VW
Performance Specification
Cooling capacity ※1 kW 14.1 23.4 27.3 43.0 48.0
Heating capacity ※ 2 kW 2.8 3.0 3.1 9.1 10.0
Operable ambient
temperature range
2 to 45 (2 to 50 when using option) 2 to 45
Cooling water
temperature range
5 to 45
Operable fluid
temperature range
3 to 35 (0 to 35: when brine is used) * 8
Control accuracy ※3 ± 0.1 ° C (± 2.0 ° C in energy saving mode setting)
Operating flow rate L / min 15 to 60 60 to 170 100 to 230
Power Specifications
Power source ※ 4 V (Hz) Three phases 200 ± 10% (50), three phases 200 to 220 ± 10% (60)
Power consumption ※1 kW 5.1 8.8 10.1 12.7 15.3
Electric current ※1 A 19.2 31.8 33.0 41.0 48.2
Power capacity ※5 kVA 8.0 12.2 12.6 17.5 19.5
Breaker capacity ※6 A 30 50 75
Operation control system Compressor speed control
Equipment details
compressor Construction Totally sealed rotary type (inverter driven) All sealed type scroll type (inverter driven)
output kW 1.7 3 4.6 7.46 11.19
Condenser Double pipe type water-cooled type
Heat
Exchanger
Construction Plate type heat exchanger
Material SUS 316 (brazing: Cu)
Discharge
pump
Construction Multistage swirl immersion type
output kW 1.1 (inverter driven) 2.0 (inverter driven) 2.5 (inverter drive) 3.7 (inverter driven)
Water tank capacity L About 60 About 90 About 100
Refrigerant R410A
Outside dimensions
(height × depth × width)
mm G 1: 1410
(G 2: 1536) × 752 × 720
1700 × 854 × 870 1410 × 854 × 1380
Unit mass(dry weight) kg G1: 200 · G2: 205 280 290 390 405
Operating noise level ※5 dB 58 59
※1 During operation at cold water temperature of 20 ° C and ambient temperature of 32 ° C. The cooling capacity is 95% or more of the display capacity.
※2 It varies with ambient temperature only during start-up operation.
※3 When the current load within ± 10% continues and ambient temperature · power supply etc is stable. However, except at startup and when the compressor turns on and off with less cooling load.
※4 The phase unbalance of power supply voltage should be within ± 3%.
※5 Maximum operating current within the operating range.
※6 It incorporates an overcurrent protection combined type earth leakage breaker as standard.
※7 The driving sound is 1 m front and 1 m high.
※8 Please use antifreezing liquid from 0 ° C to 3 ° C as the setting liquid temperature.
※9 Clean water and 30 to 40% industrial ethylene glycol aqueous solution are recommended for liquid (cold water) used in this machine. However, when using an industrial ethylene glycol aqueous solution of 30 to 40%, please note that the cooling capacity drops by about 10% . Also, in the case of pure water, please set the electric conductivity to 1 μS / cm or more.
※10 Apparatus exhaust heat quantity (kW) is about 1.3 times the cooling capacity

Cooling Capacity Diagram : Air Cooled Model Cooling Power Comparison Diagram

Cooling Water Flow Rate (For the water cooled condenser)

  • Actual cooling water flow rate will depend on the water temperature.
  • Ensure the required quantity of water as shown in the graphs below.

External Dimensions : Air Cooled Model External Dimensions

External Dimension table(units : mm)
Model W H A B C D E F G J K L M
RKE3750B-V 720 1410 826 830 708 752 791 330 197 197 115 126 1536
RKE5500B-V 870 1700 975 990 812 854 940 480 121 221 110 - -
RKE7500B-V
RKE11000B-V 1380 1700 1485 1500 812 854 1450 480 123 223 110 - -
RKE15000B-V 1610 1800 1715 1730 812 854 1680 480 124 224 110 - -

Chilled Water Flow Chart